The infrared sensor of the automatic door generally has 4 wires connected to the terminal of the automatic door control board, and two of them are power lines, which are not required. The other two are the control lines. At the wiring of the automatic door control panel, the infrared sensor control line is removed. The terminals that are connected to the two control lines of the automatic door control board are respectively connected to the automatic door anode lock COM1 and NO1 control points. Remember not to connect other contacts. In the automatic door anode lock, two open door signals NO contacts are connected and connected. Switch button, access control card machine, remote control, infrared sensor.

If you need to swipe your door, use the infrared sensor to open the Automatic door . The wiring method is the same as above, and the infrared sensor control line is connected to the automatic door anode lock to build two open door signal NO contacts. We have rich engineering construction experience and superb construction technology to meet customer needs. , sustainable service is our consistent philosophy. The company adheres to the “only professional, can excellence” goal: to provide customized security solutions for different customers!    https://www.kth-automaticdoor.com/